Radio Frequency Instrument
RF radio frequency instrument, the new pinnacle of non-surgical lifting technology RF radio frequency treatment, targeted focus radio frequency energy, beyond the surface layer of skin, directly to the subcutaneous SMAS fascia layer, stimulating fascial contraction, regeneration, non-invasive deep lifting, skin restoration and firming, and lifting of the skin. The firming and lifting treatment for sagging, fleshy, and puffy faces is very advantageous.
Key Words:
Radio Frequency Instrument
Category:
Thermal RF/RF Skin Tightening
Home Using Machine
Top Sales
Salable Beauty Machine
New Product
ODM
Hot Sales
WhatsApp:
Email:
Radio Frequency Instrument
Product Parameters
Black 7th Generation RF Ice Sculptor
Product size: 104.5*49*45.5CM Frequency: 50Hz
Rated voltage: 110-240v Weight: 8kg (including carton)
Power: 350W
Principle
1. Focusing radio frequency energy, passing through the surface skin, directly reaching the subcutaneous SMAS fascia layer, causing the polar water molecules in the fascia layer to resonate at a wave phase of 40 million times per second, and the friction of the water molecules generates heat, and then the entire layer of the SMAS fascia is accurately and evenly heated to 60°~65℃.
2. Collagen contraction: After the collagen is heated, the molecular shape undergoes structural changes, which manifests as a stable form of immediate contraction, so that the sagging skin can be immediately tightened and lifted.
3. Collagen regeneration: Heat aggregation will induce the body's wound healing response, causing collagen fibroblasts to begin to continuously release collagen, promoting fibroblast division at 40 times the speed, and the newly born fibroblasts can continuously proliferate new collagen, reconstructing a high-precision mesh subcutaneous support structure without any leaks, restoring the support and lifting functions of youth, and restoring the aging, sagging skin to a firm and upward youthful state.
Advantage
1. Air heating and deep focusing: making non-invasive deep SMAS lifting possible!
![]() |
![]() |
2. Seamless lifting, fully activating the SMAS layer:
The extremely fast frequency-changing radio frequency wave energy is focused on the entire SMAS fascia in the form of spherical waves, fully activating the regeneration and rapid synthesis of more than 90% of the damaged collagen and elastin in the fascia layer. The support and lifting effect is more than 3 times that of ultrasonic scalpel, bringing a more lasting and perfect "all-in seamless lifting" experience.
![]() |
![]() |
Effect
It can tighten the skin and shrink pores, and can also help improve wrinkles and sagging on the skin. RF radio frequency waves can penetrate deep into the skin, stimulate collagen regeneration, help rearrange fibrous tissue, and facilitate local repair.
![]() |
![]() |
Before | After |
![]() |
![]() |
Before | After |
![]() |
![]() |
Before | After |
![]() |
![]() |
![]() |
![]() |
Before | After | Before | After |
![]() |
![]() |
Before | After |
![]() |
![]() |
Before | After |
Operation surface and instructions
Thank you very much for your trust and use;
Please read the precautions in the operation manual carefully before use, and keep it properly after reading for easy reference at any time;
![]() |
![]() |
First Step | Step Two |
![]() |
![]() |
Third Step | Fourth Step |
Click Help in the upper right corner of the display screen for detailed operating instructions and precautions, etc.
Instrument accessories
RF Head Detailed Introduction
Deeply penetrate + reduce fine lines + promote absorption
High-energy focused positioning radar waves directly reach the SMAS fascia layer to achieve the effect of lifting and tightening without damaging other skin tissues. It has the advantages of being safe, stable and fast.
RF Thermal Energy
The dermis is heated up, collagen grows, wrinkles are smoothed, and skin metabolism and collagen proliferation are promoted, thereby removing wrinkles, making the skin more elastic and restoring youthful skin.
Improves absorption effect Skin dissection diagram
![]() |
![]() |
![]() |
After one month the skin gradually improves and becomes more radiant |
After two months the facial wrinkles are reduced and the contours are reshaped |
After three months the skin becomes more elastic, lifted and firm |
Ice Sculpture Head Details
Firming and lifting + contouring + anti-aging
"Comprehensive" shaping of three-dimensional contours
Principle display
![]() |
![]() |
Product Information
Tips
1) The probe must be in close contact with the skin during operation.
2) The beautician should communicate with the customer when adjusting the intensity.
3) After the operation, clean the skin with a hot towel.
4) When caring, use circular or linear movements. Do not stay in the same part all the time. The movements should be continuous or pulled up.
Accessory care
1. After each operation, clean the probe in time and wash it with saline. Do not put the entire probe into the water for cleaning. Use a wet soft cloth to wipe it.
2. Because the operating probe has a heating effect, it cannot be placed directly on the hanger after use. Wait for the probe to cool down before gently placing it on the accessory hanger
3. The accessory hanger cannot be wiped with alcohol. Use saline for cleaning.
Precautions
1. Warning
1) The instrument is a high-precision electronic instrument. When storing and placing it, it must not be placed in a humid place.
2) The instrument is fully controlled by a computer full-automatic chip. Therefore, when using it, try not to use high-frequency electrical appliances around it to avoid interfering with the normal operation of the instrument. (Such as electric curlers, hair dryers, microwave instruments, etc.). If interference occurs, there are generally two phenomena (A. During normal use, it suddenly freezes B. The LCD screen jumps randomly). The general elimination method is to turn off the power and restart the instrument.
3) Do not drop or collide with it.
4) The main unit and accessories of the instrument generally need to be cleaned and maintained regularly, especially to prevent water from entering the inside of the instrument.
5) If it is not used for a long time, it is best to use a moisture-proof and dust-proof bag to protect the entire instrument. It is best to power it on for one hour every 15 days to prevent the internal electronic components from getting damp and aging.
2. Note
Do not use the device under the following circumstances:
1) When the power plug or wire is damaged or hot;
2) When the socket is loose or shaking;
3) Do not damage, process, excessively bend or twist the plug;
4) Do not forcefully unplug the plug during operation;
5) Do not use other power cords;
6) Place the device out of reach of infants and young children;
7) Do not use chemicals to wipe the device.
8) Do not unplug the plug with wet hands;
Maintenance and care
1) Each accessory is a precision device, so you must pay attention to maintenance during and after use to avoid shortening its service life.
2) The accessories should be handled with care, and you must pay attention to holding the handle. Do not hold the output line at will, which may cause the internal connection of the accessories to loosen, resulting in poor contact and short circuit.
3) After using the accessories, do not throw them away at will. Use cleaning fluid and a clean cloth to clean them carefully and put them on the rack. It is recommended to use physiological saline or a small amount of detergent to clean the surface.
4. In case of failure, directly contact Party A's after-sales service department, and the engineer will coordinate and deal with the instrument failure.
5. After the free warranty period ends, Party A will provide a lifetime paid warranty for the instrument.
No free warranty service is provided for the following faults caused by personal reasons.
A. Faults caused by unauthorized disassembly, modification of this product;
B. Faults caused by careless dropping or falling;
C. Faults caused by lack of reasonable maintenance; Faults caused by failure to follow the correct instructions for use.
D. Faults caused by failure to follow the correct instructions for use.
The design specifications of our company's products are subject to change without prior notice. If you have any questions, please contact the company.
Maintenance Record Table |
||
Product Name: Purchase Date: Warranty Expiration Date: |
||
Dealer Name: Address: Telephone: |
||
Customer store name: Address: Telephone: |
||
Maintenance date |
Cause of failure |
Maintenance content |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Skin differences in different areas
Effect
Before and after use
![]() |
![]() |
Before | After |
![]() |
![]() |
Before | After |
![]() |
![]() |
Before | After |
RELATED PRODUCTS